1Section 61245201L1-5, Issue 361245201L1-5C
FNID and T200 FNID
Fractional T1 Network Interface Device
Installation and Maintenance
CONTENTS
1. GENERAL ............................................................................ 1
2. INSTALLATION.................................................................. 2
3. CONNECTIONS................................................................... 3
4. DSL SYSTEM TESTING .................................................... 4
5. CONTROL PORT OPERATION......................................... 4
6. DSL DEPLOYMENT GUIDELINES ................................. 11
7. TROUBLESHOOTING PROCEDURES ........................... 12
8. MAINTENANCE ................................................................ 12
9. PRODUCT SPECIFICATIONS .......................................... 12
10. WARRANTY AND CUSTOMER SERVICE .................... 12
Appendix A. FT1 Loopbacks ................................................... A-1
FIGURES
Figure 1. ADTRAN FNID ...................................................... 1
Figure 2. FNID Option Switch Locations .............................. 2
Figure 3. FNID Network Loop Connection Locations .......... 4
Figure 4. RS-232 (DB9) Pin Assignments ............................. 4
Figure 5. Introductory Menu Screen ...................................... 7
Figure 6. HDSL Main Menu Screen ...................................... 7
Figure 7. Current System Status Screen................................. 8
Figure 8. Performance History Screen ................................... 8
Figure 9. Loopback Options Screen ....................................... 9
Figure 10. Self Test Options Screen ........................................ 9
Figure 11. Provisioning Options Screen ................................. 10
Figure 12. Troubleshooting Screen ......................................... 10
Figure 13. DSL Deployment Guidelines................................. 11
Figure A-1. FT1 Loopbacks .................................................... A-1
Figure A-2. FT1 DP Network Loopback ................................. A-1
Figure A-3. FT1 DP CPE Loopback ....................................... A-1
Figure A-4. FT1 Repeater #1 or # 2 Network Loopback ........ A-2
Figure A-5. FNID Network Loopback .................................... A-2
Figure A-6. FNID CPE Loopback ........................................... A-2
TABLES
Table A. Front Panel Functions ............................................. 3
Table B. FNID Card Edge Pin Definitions ........................... 3
Table C. Definition of Screen Abbreviations ........................ 5
Table D. Loop Insertion Loss Data....................................... 11
Table E. Troubleshooting Guide .......................................... 12
Table F. FNID Unit Specifications ...................................... 13
Table A-1. FT1 Loopback Select Codes ................................ A-3
1. General
This practice is an installation and maintenance (I/M)
guide for the ADTRAN Fractional T1 Network
Interface Device (FNID). Figure 1 is an illustration of
the ADTRAN FNID.
Revision History
This practice has been reissued to reflect additional
support detail for two FT1 repeater applications.
The ADTRAN FNID is a network terminating unit
used to deploy a fractional T1 circuit using 2-wire
metallic facilities on CSA loops. This practice is
written to support both the T200 FNID circuit pack
(P/N 1245201L1) and the FNID standalone
(P/N 4245201L1) units.
The FNID is housed in a standalone metal enclosure.
The T200 FNID card plugs into a standard Type
200/400 multiple mounting shelf.
Section 61245201L1-5C
Issue 3, September 1999
CLEI Code: NCDIFBH4 _ _
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
Figure 1. ADTRAN FNID
DSL
FNID
1245201L1
DS1
SF
AMI
(GRN)
(GRN)
ESF
B8ZS
(YEL)
(YEL)
LBK
LOC
L
B
K
REM
R
S
2
3
2
TX
RX
M
O
N
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - Installation and Maintenance

1Section 61245201L1-5, Issue 361245201L1-5CFNID and T200 FNIDFractional T1 Network Interface DeviceInstallation and MaintenanceCONTENTS1. GENERAL ...

Page 2 - C A U T I O N !

10 Section 61245201L1-5, Issue 3 61245201L1-5CFigure 11. Provisioning Options ScreenPROVISIONING ___________________________________________________

Page 3

11Section 61245201L1-5, Issue 361245201L1-5CFigure 13. DSL Deployment Guidelines6. DSL DEPLOYMENT GUIDELINESThe ADTRAN FT1 DSL system is designed to

Page 4

12 Section 61245201L1-5, Issue 3 61245201L1-5C7. TROUBLESHOOTING PROCEDURESTable E is a troubleshooting guide for the FNID.8. MAINTENANCEThe ADTRAN

Page 5

13Section 61245201L1-5, Issue 361245201L1-5CLoop Interface:Modulation Type ... 2B1QMode...

Page 6

A-1Section 61245201L1-5, Issue 361245201L1-5CAppendix AFT1 Loopbacks1. GENERALThis Appendix is an overall reference to the loopbackcapabilities of th

Page 7

A-2 Section 61245201L1-5, Issue 3 61245201L1-5CThere is one loopback available to the FT1 Repeaters.The FT1 Repeater Network loopback is a digitalloop

Page 8

A-3Section 61245201L1-5, Issue 361245201L1-5C3. LOOPBACK ACTIVATION/DEACTIVATIONThis section describes loopback activation anddeactivation methods fo

Page 9

2 Section 61245201L1-5, Issue 3 61245201L1-5CWith the exception of the physical dimensions of theunits, the FNID and T200 FNID units are functionallyi

Page 10

3Section 61245201L1-5, Issue 361245201L1-5C3. CONNECTIONSAll connections of the FNID are made through cardedge connectors. Table B gives the card edg

Page 11

4 Section 61245201L1-5, Issue 3 61245201L1-5C5. CONTROL PORT OPERATIONThe FNID provides a faceplate-mounted DB9connector that supplies an RS-232 inte

Page 12

5Section 61245201L1-5, Issue 361245201L1-5CFrom the Main menu the following screens can be accessed.1. Current System Status2. Performance History3. A

Page 13

6 Section 61245201L1-5, Issue 3 61245201L1-5CA measure of signal quality for each HDSL loop is displayedin graphic form on the bottom right and left o

Page 14 - Repeater

7Section 61245201L1-5, Issue 361245201L1-5CFigure 5. Introductory Menu Screen ADTRAN

Page 15

8 Section 61245201L1-5, Issue 3 61245201L1-5CFigure 7. Current System Status Screen FT1-DP CURRENT SYSTEM STATUS FN

Page 16

9Section 61245201L1-5, Issue 361245201L1-5CFigure 9. Loopback Options ScreenLOOPBACK OPTIONS FT1-DP FNID _____

Comments to this Manuals

No comments