ADTRAN TSU 120 Specifications Page 97

  • Download
  • Add to my manuals
  • Print
  • Page
    / 128
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 96
Application Views Adtran DSU IV Application (AdDSUIVApp)
Device Management Page 97 Adtran DSU/CSU
Data Compression
This option is used to select the data compression
for the V.32 bis or V.34 operation when running
asynchronously. When enabled the system will
increase the effective data throughput to speeds
as high as 57.6kbps, depending on data type. For
synchronous applications, the speed is limited to
a maximum of 14.4 kbps for V.32 and 28.8 kbps
for V.34.
DTE Configuration View
Access: From the Icon Subviews menu for the
AdDSUIVApp, select DTE Configuration.
This view displays the following information.
DTE Rate
This option selects the DTE operating speed.
Possible speeds are bps2400, bps4800, bps9600,
bps19k, bps38k, bps56ksync-57kasync, and
sameAsLoop.
DTE Connector Type
This option selects the primary DTE connector
type for operation as either RS-232(1) or V.35.
DTE Data Scrambler
This option enables or disables DTE data
scrambler when network loop rate is operating at
64 kbps.
Command Mode
This option selects the command mode for the
primary DTE interface. Possible modes are
disable, atcmd, v25SDLC, and v25Async.
Command Echo
This option enables or disables command echo
when in AT Command Mode.
Result Code
This option enables or disables command
response when in AT Command Mode.
Code Format
This option selects short or long AT command
response format when in AT Command Mode.
Anti-stream Timeout
This option selects the anti-stream timeout. The
anti-stream timeout is the maximum time the
DSUIV transmits data into the network from the
DTE. This feature is used in multi-drop networks
to prevent one DTE from continuously sending to
a master DSUIV. The anti-stream timer runs
when the request to send (RS) lead is active.
Possible values are disable, sec10, sec30, and
sec60.
CS Option
This option selects mode of operation for DTE
clear to send (CS) lead. Possible modes are
forcedOn, followRS, onWithCD, onWithRSCD,
Page view 96