B-24 61184002L3-5B
Menus TL1 Command S
y
ntax
Working Errored Seconds RTRV-PM-OC3:<tid>:1-1:<ctag>::ESS,0-UP,NEND,,15-MIN,ALL;
Working Severely Errored Seconds RTRV-PM-OC3:<tid>:1-1:<ctag>::SESS,0-UP,NEND,,15-MIN,ALL;
Protect Code Violations RTRV-PM-OC3:<tid>:1-2:<ctag>::CVS,0-UP,NEND,,15-MIN,ALL;
Protect Errored Seconds RTRV-PM-OC3:<tid>:1-2:<ctag>::ESS,0-UP,NEND,,15-MIN,ALL;
Protect Severely Errored Seconds RTRV-PM-OC3:<tid>:1-2:<ctag>::SESS,0-UP,NEND,,15-MIN,ALL;
Daily Thresholds
Code Violations Enable not accessible from TL1
Errored Seconds Enable not accessible from TL1
Severely Errored Seconds Enable not accessible from TL1
Code Violations Value SET-TH-OC3:<tid>::<ctag>::CVS,<value>,,,1-DAY
<value> is an integer
Errored Seconds Value SET-TH-OC3:<tid>::<ctag>::ESS,<value>,,,1-DAY
<value> is an integer
Severely Errored Seconds Value SET-TH-OC3:<tid>::<ctag>::SESS,<value>,,,1-DAY
<value> is an integer
Quarter Hourly Thresholds
Code Violations Enable not accessible from TL1
Errored Seconds Enable not accessible from TL1
Severely Errored Seconds Enable not accessible from TL1
Code Violations Value SET-TH-OC3:<tid>::<ctag>::CVS,<value>,,,15-MIN
<value> is an integer
Errored Seconds Value SET-TH-OC3:<tid>::<ctag>::ESS,<value>,,,15-MIN
<value> is an integer
Severely Errored Seconds Value SET-TH-OC3:<tid>::<ctag>::SESS,<value>,,,15-MIN
<value> is an integer
Clear Current Interval not accessible from TL1
OC3 Line
Daily
Working Code Violations RTRV-PM-OC3:<tid>:1-1:<ctag>::CVL,0-UP,NEND,,1-DAY,ALL;
Working Errored Seconds RTRV-PM-OC3:<tid>:1-1:<ctag>::ESL,0-UP,NEND,,1-DAY,ALL;
Working Severely Errored Seconds RTRV-PM-OC3:<tid>:1-1:<ctag>::SESL,0-UP,NEND,,1-DAY,ALL;
Working Unavailable Seconds RTRV-PM-OC3:<tid>:1-1:<ctag>::UASL,0-UP,NEND,,1-DAY,ALL;
Working Fault Count RTRV-PM-OC3:<tid>:1-1:<ctag>::FC-L,0-UP,NEND,,1-DAY,ALL;
Working Protection Switch Count RTRV-PM-OC3:<tid>:1-1:<ctag>::PSC-L,0-UP,NEND,,1-DAY,ALL;
Protect Code Violations RTRV-PM-OC3:<tid>:1-2:<ctag>::CVL,0-UP,NEND,,1-DAY,ALL;
Protect Errored Seconds RTRV-PM-OC3:<tid>:1-2:<ctag>::ESL,0-UP,NEND,,1-DAY,ALL;
Protect Severely Errored Seconds RTRV-PM-OC3:<tid>:1-2:<ctag>::SESL,0-UP,NEND,,1-DAY,ALL;
Protect Unavailable Seconds RTRV-PM-OC3:<tid>:1-2:<ctag>::UASL,0-UP,NEND,,1-DAY,ALL;
Protect Fault Count RTRV-PM-OC3:<tid>:1-2:<ctag>::FC-L,0-UP,NEND,,1-DAY,ALL;