Ethernet Traffic Generation & Monitoring Test
170 AXS-200/805/855
Sequence Results
Sequence Results
Press , select ETHERNET, Traffic Generation & Monitoring, Results,
and the Sequence tab.
Statistics for Frame Loss Parameters
Frame Loss is declared when a missing sequence number is not received
within the next 20 ms. The frame loss parameters are applied to the main
stream only.
³ Seconds: Displays the total number of seconds in which one or
more Frame Loss event occurred.
³ Count: Displays the total
number of times the Frame
Loss event occurred.
³ Rate: Displays the rate of
frames that are lost during
transmission.
³ Threshold: Set the threshold
value for Count or Rate as per the
selected type of verdict. See
Frame Loss Pass/Fail Verdict on
page 142.
= PASS
= FAIL