DESCRIPTION
TheOC‐12SmallForm‐FactorPluggableCWDM1491nm(SFP
OC‐12)plugsintoADTRANOC‐12equipmentdesignedtoaccept
SmallForm‐factorPluggables(SFPs).
Installedintoanappropriatehostunit,theSFPOC‐12providesan
OC‐12CWDMinterfacetothesupportingsystem.
Toensurecompatibility,refertothedocumentationprovided
withthehostmodule.
ThefollowingfeaturesaresupportedontheSFPOC‐12:
♦ SONETOC‐12compatible(622.08Mb/s)1491nm,
longreach,single‐mode,2‐fiberoperation
♦ 80kmmaximumopticalspan
Duetocompliancecertificationrequirements,useonly SFPs
suppliedbyADTRANwiththehostmodule.ADTRANcannot
certifysystemintegritywithotherSFPs.
SPECIFICATIONS
♦ OpticalSpecifications:
◊ Opticaltransmitlevel:–3dBmto+5dBm
◊ Opticalreceivelevel:–28dBmto–8dBm
◊ Powerpenalty:–1dB
◊ Opticalbudget:24(±1)dBm
◊ Minimumspanattenuation:13dB
◊ Opticalconnectors:LC
♦ ExtendedEnvironmentalSupport:
◊ Operationaltemperaturerange:–40°Cto+65°C
◊ Storagetemperaturerange:–40°Cto+85°C
◊ Relativehumidityto95%,noncondensing
OC-12 Small Form-Factor Pluggable
CWDM 1491 nm
INSTALLATION
ToinstalltheSFPOC‐12intoanappropriatemodule,complete
thefollowingsteps:
1. InspecttheSFPOC‐12.Ifdamaged,fileaclaimwiththecar‐
rierandthencontactADTRANCustomerSupport.
DonotremovetheprotectiveendcapfromtheSFPuntilthefiber
opticcableisreadytobeconnected.
2. InserttheSFPOC‐12intotheSFPcageonthemodule.
Ensurethatthemanufacturer’slabelontheSFPisfacing
upwardforcorrectinstallation.
3. SlidetheSFPOC‐12allthewayintothereceptacleuntil
thereisanaudible“click”.
ThelatchontheSFPisusedtoremovetheSFPfromthecageon
thecircuitcard.
PROVISIONING
The SFPOC‐12 is not directly provisionable. To provision the
SFPOC‐12, access the menu system of the host module.
Refer to the “Provisioning” section of the Job Aid or I&M
provided with the host module for provisioning details.
SAFETY AND REGULATORY COMPLIANCE
ElectrostaticDisc harge (ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewriststrap
topreventdamagetoelectroniccom pon ents .Placemodulesin
antistaticpackingmaterialwhentransportingorstoring.When
wor kin g on modules, always placethem on an approved
antistaticmatthatiselectricallygrounded.
TheSFPOC‐12isNRTLListedtotheapplicableULstandards.
TheSFPOC‐12meetsorexceedsalltheapplicablerequirements
ofNEBS,TelcordiaGR‐63‐CORE,GR‐1089‐CORE,andETSIEN
300368.
TheSFPOC‐12isintendedfordeploymentin
CentralOfficetype
facilities,EEEs,EECs,andlocationswheretheNECapplies(for
example,CustomerPremises).TheSFPOC‐12istobeinstalledin
ADTRANproductsinRestrictedAccessLocationsonly,and
installedbytrainedservicepersonnel.
CLEI: SOOTAKNJ_ _
Product P/N: 1442703PG2
Issue Date: December 2010
Document P/N: 61442703PG2-22B