61181300L1-5C Section 61181300L1-5C, Issue 3 1
Section 61181300L1-5C
Issue 3, October 2000
CLEI Code # M3O1CD0C_ _
Total Access
TM
QFO-C
Installation and Maintenance
1. GENERAL
This practice is an installation and maintenance guide
for the ADTRAN Total Access QFO-C, P/N
1181300L1, illustrated in Figure 1. See Table 5 for a
description of QFO-C front panel indicators.
Revision History
This is the third issue of this practice. This issue includes
the removal of the four-character display (FCD)
five-minute time out feature.
Features
The Total Access QFO-C carries up to four
asynchronous DS1 circuits over a single-mode fiber
pair with an optical budget of 22 dB (minimum). The
Total Access QFO-C has the following features:
CONTENTS
1. GENERAL ............................................................................ 1
2. INSTALLATION .................................................................. 2
3. OPERATION ........................................................................ 5
4. MAINTENANCE ................................................................ 28
5. WARRANTY AND CUSTOMER SERVICE ................... 28
FIGURES
Figure 1. Total Access QFO-C .............................................. 1
Figure 2. Total Access 3000 CO Mounting Shelf ................. 5
Figure 3. Fiber Optic Receiver Cabling ................................. 6
Figure 4. QFO-C FCD Menu Tree ....................................... 10
Figure 5. Fiber Main Menu Screen ...................................... 12
Figure 6. QFO-C Configuration Screen............................... 12
Figure 7. Provisioning Screen .............................................. 13
Figure 8. Service State Screen ............................................. 13
Figure 9. Port Service Status Screen.................................... 14
Figure 10. Provisioning of All Ports Screen .......................... 14
Figure 11. DSX Equalization Screen ..................................... 15
Figure 12. Loopback Timeout Screen.................................... 15
Figure 13. AIS to DSX (Loss of T1) Screen ......................... 16
Figure 14. AIS to DSX (FLOS) Screen ................................. 16
Figure 15. Restore Factory Defaults Screen .......................... 17
Figure 16. Status Screen ......................................................... 17
Figure 17. Port Status Screen ................................................. 18
Figure 18. Status of All Ports Screen ..................................... 18
Figure 19. Alarms Screen ....................................................... 19
Figure 20. Alarm Reporting Screen ....................................... 19
Figure 21. Alarm Provisioning Screen .................................. 20
Figure 22. ES Threshold (15-Minutes) Screen ...................... 20
Figure 23. SES Threshold (15-Minutes) Screen.................... 21
Figure 24. UAS Threshold (15-Minutes) Screen .................. 21
Figure 25. ES Threshold (24-Hours) Screen ......................... 22
Figure 26. SES Threshold (24-Hours) Screen ....................... 22
Figure 27. UAS Threshold (24-Hours) Screen ...................... 23
Figure 28. Test Screen ............................................................ 23
Figure 29. Port Test Screen .................................................... 24
Figure 30. Loopback RT Screen ............................................ 24
Figure 31. Loopback DSX Screen ......................................... 25
Figure 32. Performance Monitoring Screen .......................... 25
Figure 33. Port Performance Monitoring Screen .................. 26
Figure 34. Protection Switch Screen ..................................... 26
Figure 35. Protection Switch Activate Screen ....................... 27
Figure 36. Circuit ID Screen .................................................. 27
Figure 37. Port Current Circuit ID Screen ............................. 28
TABLES
Table 1. Compliance Codes .................................................. 2
Table 2. QFO-only Populated Total Access Chassis ........... 2
Table 3. Pin-out for Pair 5 and 7 on TA 3000 ...................... 3
Table 4. Pin-out for Pair 6 and 8 on TA 3000 ...................... 3
Table 5. Pin-out for Pair 5 and 7 on TA 3010 ...................... 4
Table 6. Pin-out for Pair 6 and 8 on TA 3010 ...................... 4
Table 7. QFO-C Front Panel Indicators ............................... 7
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
Figure 1. Total Access QFO-C
QF0-C
DSX
PWR
DSX
DSX
TST
ALM
ACT
A
P
S
GRN = NORM
YEL = MAN
1181300L1
DSX
#2
#3
#4
#1
Table 8. QFO-C Provisioning Options ................................. 8
Table 9. QFO-C Menu Hierarchy ....................................... 11
Table 10. QFO-C Specifications .......................................... 29
Page view 0
1 2 3 4 5 6 ... 29 30

Summary of Contents

Page 1 - Installation and Maintenance

61181300L1-5C Section 61181300L1-5C, Issue 3 1Section 61181300L1-5C Issue 3, October 2000CLEI Code # M3O1CD0C_ _Total AccessTM QFO-CInstallation and

Page 2 - Table 1. Compliance Codes

10 Section 61181300L1-5C, Issue 3 61181300L1-5CFigure 4. QFO-C FCD Menu TreeSTAT VIEW PROVSRVCSTATDEXEQLBTOUTAIS TODSXLOSAIS TODSXFLOSDSBL ENBLSAVENOS

Page 3

61181300L1-5C Section 61181300L1-5C, Issue 3 11Table 9. QFO-C Menu HierarchyQFO-C Main MenuConfigurationProvisioningService StatePort 0/1/2/3/4All Pr

Page 4

12 Section 61181300L1-5C, Issue 3 61181300L1-5CShelf: Slot: 10 Total Access System 07/15/99 10:37Unacknowledged Alarms:

Page 5 - 123456789

61181300L1-5C Section 61181300L1-5C, Issue 3 13Figure 8. Service State ScreenShelf: Slot: 10 Total Access System 07/15

Page 6 - Fiber Optic Transceiver

14 Section 61181300L1-5C, Issue 3 61181300L1-5CFigure 10. Provisioning of All Ports ScreenShelf: Slot: 10 Total Access System

Page 7 - Navigating the Menu Structure

61181300L1-5C Section 61181300L1-5C, Issue 3 15NOTEPort 0 (all ports) “Out of Service” disables theentire module. Port 0 must be “In Service” forany

Page 8

16 Section 61181300L1-5C, Issue 3 61181300L1-5CFigure 13. AIS to DSX (Loss of T1)Shelf: Slot: 10 Total Access System 07/1

Page 9

61181300L1-5C Section 61181300L1-5C, Issue 3 17Figure 15. Restore Factory Defaults ScreenShelf: Slot: 10 Total Access System

Page 10

18 Section 61181300L1-5C, Issue 3 61181300L1-5CShelf: Slot: 10 Total Access System 07/15/99 10:43Unacknowledged Alarms:

Page 11 - • Module power supply failure

61181300L1-5C Section 61181300L1-5C, Issue 3 19Shelf: Slot: Total Access System 02/18/98 02:24:18Unacknowledged Alarm: NoneAlarms

Page 12

2 Section 61181300L1-5C, Issue 3 61181300L1-5C• Installs in both the Total Access 3000 (23-inch)and the Total Access (19-inch) chassis.• End-to-end tr

Page 13

20 Section 61181300L1-5C, Issue 3 61181300L1-5CShelf: Slot: Total Access System 02:24:18 02/18/98Unacknowledged Alarm: NoneES Thresho

Page 14

61181300L1-5C Section 61181300L1-5C, Issue 3 21Figure 24. UAS Threshold (15-Minute) ScreenShelf: Slot: Total Access System 02/18/98 02:24:18Unackn

Page 15 - Changing the DSX Equalization

22 Section 61181300L1-5C, Issue 3 61181300L1-5CFigure 25. ES Threshold (24-Hour)Shelf: Slot: Total Access System 02:24:18 02/18/98

Page 16

61181300L1-5C Section 61181300L1-5C, Issue 3 23Figure 28. Test ScreenShelf: Slot: Total Access System 02/18/98 02:24:18Unacknowledged Alarms: None

Page 17 - Accessing the Status Screen

24 Section 61181300L1-5C, Issue 3 61181300L1-5CFigure 29. Port Test ScreenShelf: Slot: Total Access System 02:24:18 02/18/98Unacknowledged Alarms: No

Page 18

61181300L1-5C Section 61181300L1-5C, Issue 3 25Figure 32. Performance Monitoring ScreenShelf: Slot: Total Access System 02:24:18 02/18/98Unacknowled

Page 19 - Viewing Alarms

26 Section 61181300L1-5C, Issue 3 61181300L1-5CShelf: Slot: Total Access System 02/18/98 02:24:18Unacknowledged Alarms: None APS Switching 1.

Page 20 - Alarm Provisioning

61181300L1-5C Section 61181300L1-5C, Issue 3 27Shelf: Slot: Total Access System 02/18/98 02:24:18Unacknowledged Alarms: None Circuit ID

Page 21

28 Section 61181300L1-5C, Issue 3 61181300L1-5C2. Type the number of the corresponding port whoseCircuit ID is to be set or changed and press Enter. T

Page 22

61181300L1-5C Section 61181300L1-5C, Issue 3 29Table 10. QFO-C SpecificationsDS1Input Level ...

Page 23

61181300L1-5C Section 61181300L1-5C, Issue 3 3Table 3. Pin-out For Pair 5 and 7 on TA 3000Table 4. Pin-out For Pair 6 and 8 on TA 3000roloCpuorGredn

Page 24 - Performing Loopback Testing

30 Section 61181300L1-5C, Issue 3 61181300L1-5C

Page 25 - Loopback DSX: Disabled

4 Section 61181300L1-5C, Issue 3 61181300L1-5CIf the system is configured with only QFO-Cs, all fourDSX-1 connections are made. The connections arema

Page 26

61181300L1-5C Section 61181300L1-5C, Issue 3 5If no protection switching is provided, the Main unitplugs into any odd-numbered slot. The next higher

Page 27 - Setting the Port Circuit ID

6 Section 61181300L1-5C, Issue 3 61181300L1-5CRelease the card retention lever and carefully seatthe card into the backplane connector by firmlypressi

Page 28

61181300L1-5C Section 61181300L1-5C, Issue 3 7Table 7.QFO-C Card ProvisioningThe card is provisioned through the craft port on theSCU or by the FCD.

Page 29

8 Section 61181300L1-5C, Issue 3 61181300L1-5COption DescriptionService State Enables normal connection to the DSX or multiplexerinterfaceLoops will t

Page 30

61181300L1-5C Section 61181300L1-5C, Issue 3 9• ESCAPE – press the switch in the MODEdirection and release it between 1.5 seconds and3 seconds to asc