Summary of Contents

Page 1 - TSU 600e

TSU 600eUser ManualPart Number 1202076L1 July 199761202.076L1-1A

Page 2

Table of Contentsvi Product Name Doc. Number ...

Page 3

Table of ContentsDoc. Number Product Name vii Agent Card snmp access... 73S

Page 4

Table of Contentsviii Product Name Doc. Number

Page 5

61202.076L2-1 TSU 600e User Manual 9 Chapter 1Introduction TSU 600e OVERVIEW The TSU 600e is a T1-FT1 CSU/DSU multiplexer with six option slots and em

Page 6

Chapter 1: Standard Features in the TSU 600 and TSU 600e10 TSU 600e User Manual 61202.076L2-1 • Enhanced terminal mode.• Support for a backup power su

Page 7

Chapter 1: TSU 600e Option Modules61202.076L2-1 TSU 600e User Manual 11 TSU 600E CONFIGURATION APPLICATIONS The following examples illustrate possible

Page 8

Chapter 1: All Voice Application12 TSU 600e User Manual 61202.076L2-1 All Voice Application In this application 24 voice channels are provided for te

Page 9

Chapter 1: Variations of Mixed Applications61202.076L2-1 TSU 600e User Manual 13 Figure 1-4 Drop and Insert, Voice, and Bridging Application Set Up Va

Page 10

Chapter 1: Variations of Mixed Applications14 TSU 600e User Manual 61202.076L2-1 Figure 1-5 Variations of Mixed Applications T1/FT1 OVERVIEW Telephone

Page 11

Chapter 1: T1 Service Offerings61202.076L2-1 TSU 600e User Manual 15 T1 Service Offerings T1 is a digital service that is delivered to the user over t

Page 12 - Table of Contents

Trademarks: Windows is a registered trademark of Microsoft Corp.T-Watch is a trademark of ADTRAN, Inc.901 Explorer BoulevardP.O. Box 140000Huntsville

Page 13 - Introduction

Chapter 1: Network Manager16 TSU 600e User Manual 61202.076L2-1 SNMP Simple Network Management Protocol (SNMP) broadly refers to the message protocols

Page 14

Chapter 1: MIB61202.076L2-1 TSU 600e User Manual 17 DIAL BACKUP OPERATION The TSU 600e’s DBU cards are field-installable by the customer. See the chap

Page 15 - CONFERENCING

Chapter 1: MIB18 TSU 600e User Manual 61202.076L2-1 WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within five years from th

Page 16

61202.076L1-1 TSU 600e User Manual19 Chapter 2Installation UNPACK, INSPECT, POWER UPReceipt Inspection Carefully inspect the TSU 600e for any shippi

Page 17 - TS U 6 00

Chapter 2: Power Connection20 TSU 600e User Manual 61202.076L1-1 Power Connection Each TSU 600e is equipped with a captive eight-foot power cord, term

Page 18 - T1/FT1 OVERVIEW

Chapter 2: Rear Panel 61202.076L2-1 TSU 600e User Manual 21 MODULE 1MODULE 2MODULE 3MODULE 4MODULE 5MODULE 65A/250V24/48V DC+ -ONOFFCONTROL/CHAI

Page 19 - Fractional T1

Chapter 1: 22 TSU 600e User Manual 61202.076L2-1

Page 20

Chapter 2: TSU 600e Interfaces61202.076L1-1 TSU 600e User Manual 23 TSU 600e Interfaces The TSU 600e is equipped with six slots in the rear panel to h

Page 21 - DIAL BACKUP OPERATION

Chapter 2: Slots 3-524 TSU 600e User Manual 61202.076L1-1 Slot 2 is used for the Dial Backup module if a DBU is installed. This slot accepts all othe

Page 22 - WARRANTY AND CUSTOMER SERVICE

Chapter 2: Other Data Interfaces61202.076L1-1 TSU 600e User Manual 25 • DSX1 provides connection to a digital PBX.• Full Drop and Insert permits the d

Page 23 - Installation

FCC regulations require that the following information be provided to the customer in this manual.1. This equipment complies with Part 68 of the FCC r

Page 24 - ELECTRIC SHOCK

Chapter 2: Self Test26 TSU 600e User Manual 61202.076L1-1 tion to the equipment grounding conductor in the power supply cord.The supplementary equipme

Page 25 - Chapter 2: Rear Panel

Chapter 2: Set User Passcode61202.076L1-1 TSU 600e User Manual 27 cuitry on the board.a. RAM tests; EPROM checksum.b. DS0 map tests.c. On board data p

Page 26 - Chapter 1:

Chapter 2: Set Control Port28 TSU 600e User Manual 61202.076L1-1 Unless locked out externally, the front panel can also control the unit. Chain In TS

Page 27

Chapter 2: Normal Power-Up Procedure61202.076L1-1 TSU 600e User Manual 29 Normal Power-Up Procedure After the unit has been put into operation with th

Page 28 - DIAL BACKUP

Chapter 2: Set Unit Identification30 TSU 600e User Manual 61202.076L1-1

Page 29 - Other Data Interfaces

61202.076L2-1 TSU 600e User Manual 31 Chapter 3Operation FRONT PANEL The TSU 600e front panel both monitors operation and controls the configuration o

Page 30 - Self Test

Chapter 3: Cancel32 TSU 600e User Manual 61202.076L2-1 Cancel Pressing the Cancel key stops the current activity and returns to the previous menu. Rep

Page 31 - Set Control Port

Chapter 3: Front Panel Menu Navigation61202.076L2-1 TSU 600e User Manual 33 Module, with the addition of the Error LED. The Error LED indi-cates an e

Page 32

Chapter 3: Front Panel Menu Structure34 TSU 600e User Manual 61202.076L2-1 The TSU 600e uses a multilevel menu structure containing both menu items an

Page 33 - Set Unit Identification

Chapter 3: Data Port Identification61202.076L2-1 TSU 600e User Manual 35 Build Out. The display field shows the value actually set. The equal symbol

Page 34

FEDERAL COMMUNICATIONS COMMISSIONRADIO FREQUENCY INTERFERENCE STATEMENT: This equipment has been tested and found to comply with the limits for a Clas

Page 35 - Operation

Chapter 3: Front Panel36 TSU 600e User Manual 61202.076L2-1 THREE METHODS OF CONTROLFront Panel The front panel provides complete and easy control of

Page 36

61202.076L2-1 TSU 600e User Manual 37 Chapter 4Status The Status menu branch provides the ability to view the status of the TSU 600e operation. See F

Page 37 - Front Panel Menu Structure

Chapter 4: Network Performance Reports (NI PERF RPTS)38 TSU 600e User Manual 61202.076L2-1 Network Performance Reports (NI PERF RPTS) The Network Inte

Page 38

Chapter 4: Network Interface Errors (NI ERRORS)61202.076L2-1 TSU 600e User Manual 39 Since only the user’s copy of performance data is cleared by the

Page 39 - Terminal Mode

Chapter 4: Port Status40 TSU 600e User Manual 61202.076L2-1 View History displays a history of 20 status changes in the unit, including the date, time

Page 40

61202.076L2-1 TSU 600e User Manual 41 Chapter 5Configuration The Configuration menu is used to set the TSU 600 operational con-figuration, including a

Page 41 - Chapter 4

Chapter 5: 42 TSU 600e User Manual 61202.076L2-1 Menu flow is normally depicted from left to right. Arrows on the lower right of the screen indicate

Page 42

Chapter 5: Network Timed61202.076L2-1 TSU 600e User Manual 43 TSU 600E CLOCK SOURCES The TSU 600e is operable from various clock sources permitting it

Page 43

Chapter 5: Internal Timing44 TSU 600e User Manual 61202.076L2-1 Figure 1-5 Network Timed Clock Source Internal Timing The TSU 600e is the source of ti

Page 44

Chapter 5: Network (NI)61202.076L2-1 TSU 600e User Manual 45 PBX application. Figure 1-8 Normal (CSU) The network interface and secondary interface cl

Page 45 - Configuration

Doc. Number Product Name i Table of Contents Introduction...

Page 46

Chapter 5: Network (NI)46 TSU 600e User Manual 61202.076L2-1 Network (NI) Menu Items The menu items are: FORMAT Sets the frame format for the NI. Choo

Page 47

Chapter 5: Unit61202.076L2-1 TSU 600e User Manual 47 ones at 12.5 %. Choose Enable or Disable. Unit The Unit menu changes the baud rate of the Contro

Page 48 - Internal Timing

Chapter 5: Map In Use: A(B)48 TSU 600e User Manual 61202.076L2-1 (enabled). Scroll to select Auto to enable or Off to disable the Automatic Map Change

Page 49 - Network (NI)

Chapter 5: Map In Use: A(B)61202.076L2-1 TSU 600e User Manual 49 Figure 3-15 DS0 Map Designations DS0 A and DS0 B are the current maps the TSU 600 use

Page 50

Chapter 5: Port Configuration (Port Config)50 TSU 600e User Manual 61202.076L2-1 When all entries are complete, Cancel moves the cursor to the last of

Page 51 - Map Exchange (Map Xchng)

Chapter 5: Port Configuration (Port Config)61202.076L2-1 TSU 600e User Manual 51 access by use of this menu item. The Config menus for options ports

Page 52 - Map In Use: A(B)

Chapter 5: Port Configuration (Port Config)52 TSU 600e User Manual 61202.076L2-1

Page 53

61202.076L2-1 TSU 600e User Manual 53 Chapter 6Utility Menu The utility menu tree is used to view and to set system parameters (see Figure 6-1). This

Page 54

Chapter 6: Time/Date54 TSU 600e User Manual 61202.076L2-1 return the system to the previous menu level. Pressing Cancel repeatedly returns the system

Page 55

Chapter 6: Unit ID: ID61202.076L2-1 TSU 600e User Manual 55 Pressing any key after entering a passcode causes the unit to return to the previous activ

Page 56

Table of Contentsii Product Name Doc. Number ...

Page 57 - Utility Menu

Chapter 6: Software Revision (Software Rev)56 TSU 600e User Manual 61202.076L2-1 available in limited access mode. Editing or changing the Unit ID re

Page 58

61202.076L2-1 TSU 600e User Manual 57 Chapter 7Test The Test menu initiateS different types of unit tests and to displays test results in the LCD wind

Page 59 - Unit ID: ID

Chapter 1: Self Tests58 TSU 600e User Manual 61202.076L2-1 TSU 600E TESTING The TSU 600e offers three forms of testing:• Self test• Loopback tests (lo

Page 60 - Port Utility

Chapter 1: Loopback Tests61202.076L2-1 TSU 600e User Manual 59 There are two classes of loopbacks: network interface and DTE in-terface. Network Inte

Page 61 - Chapter 7

Chapter 1: Loopback Tests60 TSU 600e User Manual 61202.076L2-1 The TSU 600e also activates a port loopback when the DTE loopback is as-serted. Figure

Page 62

Chapter 1: Pattern Generation61202.076L2-1 TSU 600e User Manual 61 Pattern Generation The TSU 600e offers two available test patterns: QRSSand 511. Q

Page 63

Chapter 1: Network Tests62 TSU 600e User Manual 61202.076L2-1 LOCAL LOOPBCK There are three available choices for setting the local loopback: Scroll

Page 64

Chapter 1: Network Tests61202.076L2-1 TSU 600e User Manual 63 patterns are available: QRSS always runs at 64K/DS0. Use the up and down scroll to selec

Page 65 - Network Tests

Chapter 1: Run Selftest64 TSU 600e User Manual 61202.076L2-1 by Map A to receive data from an Nx56/64 port and 2) by looping the far end using a V.54

Page 66

Chapter 1: Port Tests61202.076L2-1 TSU 600e User Manual 65 Port Tests The Port Tests menu is used to activate testing of specific data ports. It contr

Page 67

Table of ContentsDoc. Number Product Name iii ... 26C

Page 68 - Run Selftest

Chapter 1: Cancel Tests66 TSU 600e User Manual 61202.076L2-1

Page 69 - Cancel Tests

61202.076L2-1 TSU 600e 67 Chapter 4Example Operations This chapter provides examples of how to configure the system for a variety of operations. Voice

Page 70 - Chapter 1: Cancel Tests

Chapter 1: Prior to Step 168 TSU 600e 61202.076L2-1 information. Prior to Step 1 Complete the configuration chart. The configuration charts from t

Page 71 - Example Operations

Chapter 1:61202.076L2-1 TSU 600e 69 Step 3. The number of DS0s/Port is based on the Data Rate Table in the ap-pendix, Configure DTE Port: (1.1

Page 72

Chapter 1: Step 6. Activate Configuration Menu70 TSU 600e 61202.076L2-1 The unit displays the first two Configuration submenu items: Net-work (NI) (n

Page 73

Chapter 1: Step 6. Activate Configuration Menu61202.076L2-1 TSU 600e 71 From the first menu position scroll down or use number 5 to select the DS0

Page 74 - CONFIGURING THE DS0 MAP

Chapter 1: Step 6. Activate Configuration Menu72 TSU 600e 61202.076L2-1 Figure 4-7 Passthru Selection Field Scroll down to display the Y and press

Page 75

Chapter 1: Review61202.076L2-1 TSU 600e 73 and the PORT is 1.1 Nx56/64. At DS0 14-24, the setting of the data is accomplished by using the same incre

Page 76

Chapter 1: Edit74 TSU 600e 61202.076L2-1 somewhere between DS0 13 and 24.The map that was just created is still a Temp Map, and must be ed-ited as suc

Page 77

Chapter 1: Configuring the Ports61202.076L2-1 TSU 600e 75 The Temporary Map can be reviewed as many times as necessary. When all corrections are comp

Page 78

Table of Contentsiv Product Name Doc. Number Network (NI) Menu Items... 40FORMAT...

Page 79 - Configuring the Ports

Chapter 1: Configuring the Ports76 TSU 600e 61202.076L2-1 Scroll to continue viewing the remainder of the menu selections, comparing all the settings

Page 80

61202.076L2-1 TSU 600e 77 Appendix AUnderstanding SNMP As local area network (LAN) environments became standardized over the past ten years, multi-ven

Page 81 - Understanding SNMP

Chapter 1: Commands78 TSU 600e 61202.076L2-1 When requesting the network manager to retrieve or modify a par-ticular piece of information about a netw

Page 82 - Commands

Chapter 1: Message61202.076L2-1 TSU 600e 79 and transported over the LAN or WAN (wide area network). AGENT CARD SNMP ACCESS By default, SNMP MIB Brows

Page 83 - SNMP TRAP CONFIGURATION

Chapter 1: Message80 TSU 600e 61202.076L2-1 If individual option card port and slot identification is required, it is present in the four byte adProdP

Page 84 - SNMP MIB FILES

Chapter 1: Message61202.076L2-1 TSU 600e 81 The standard MIB files are usually included with most SNMP net-work management software. The latest versi

Page 85

Chapter 1: Message82 TSU 600e 61202.076L2-1

Page 86 - 82 TSU 600e 61202.076L2-1

61202.076L1-1 TSU 600e User Manual 83 Appendix CNetwork Pinouts WIRINGNetwork On the rear panel of the TSU 600e is an eight-position modular jack la

Page 87 - Network Pinouts

Appendix C: Control In/Chain In84 TSU 600e User Manual 61202.076L1-1 Control In/Chain In This is used as an RS-232 port for connection to a computer o

Page 88 - Control In/Chain In

Appendix C: Chain Out61202.076L1-1 TSU 600e User Manual 85 Chain Out This is used to connect to another TSU 600e Chain In connector. See Table 2-C

Page 89 - Chain Out

Table of ContentsDoc. Number Product Name v Software Revision (Software Rev)... 49Port Utility...

Page 90

Appendix C: Chain Out86 TSU 600e User Manual 61202.076L1-1 Table 2-C Chain Out Pinout PIN NAME DESCRIPTION 1 GND Ground - connected to unit chassis. C

Page 91

61202.076L2-1 TSU 600e 87 Index Symbols %AS 32 %EF 32 Numerics 511 pattern 55 A access 41 activating menu items 26 active alarms 33 ADTRAN parts

Page 92

Index88 TSU 600e 61202.076L2-1 T-Watch PRO 4 control in 16, 17, 20 control portset 20 copy A > temp 43 copy key 25 correct passcode 21 CRC 2

Page 93

Index61202.076L2-1 TSU 600e 89 inspect 11 interfaceDS1 14 DSX1 14 voice 14 interfaces 12 internal timing 37, 38 K keyalarm 25 cancel 25 clear

Page 94

Index90 TSU 600e 61202.076L2-1 operation keys 25 option modules 5 option ports 14 option slotarrangement 5 slot 1 13 slot 2 13 slot 3 13 slot 4

Page 95

Index61202.076L2-1 TSU 600e 91 set user passcode 19 setting a passcode 49 setting the data field 27 SF 40 shift key 25 SI 14 simple network mana

Page 96

Index92 TSU 600e 61202.076L2-1 voice application 7 voice interface 14 VT-100 terminal mode 29 W wiring 16 network 16 wrong passcode 22 X xmit pr