NetVanta 6240/6250 Series HIG Unit Installation
61700202G1-34B Copyright © 2013 ADTRAN, Inc. 27
Supplying Power to the Unit
The NetVanta 6240/6250 Series units come equipped with a 120 VAC, 60 Hz power supply for connecting to a
properly grounded power receptacle. (A detachable power cable with a grounded, three-prong plug comes with
the shipment.) To power this unit, connect the power cable to an appropriate AC power source.
Supplying DC Power to the NetVanta 6250
The NetVanta 6250 can also be connected to a centralized DC power source via the two-position terminal block
connector (DC IN) located on the rear of the chassis (see Figure 6 on page 28). Power and ground connections
require copper conductors and a ring lug.
In addition to the equipment earthing conductor in the power supply cord, a
supplementary equipment earthing conductor is to be installed between the system and
earth.
The supplemental earthing conductor shall be connected to the equipment using a
number 8 ring terminal and should be fastened to the grounding lug provided on the
rear panel of the equipment. The ring terminal should be installed using the
appropriate crimping tool (AMP P/N 59250 T-EAD Crimping Tool or equivalent).
The supplementary equipment earthing conductor must not be smaller in size than
cross-sectional area of not less than 2.5 mm
2
, if mechanically protected. The
supplementary equipment earthing conductor is to be connected to the product at the
terminal provided, and connected to earth in a manner that will retain the earth
connection when the power supply cord is unplugged. The connection to earth of the
supplementary earthing conductor must be in compliance with the appropriate rules for
terminating bonding jumpers in Part K of Article 250 of the National Electrical Code,
ANSI/NFPA 70, and Article 10 of Part 1 of the Canadian Electrical Code, Part 1,
C22.1. Termination of the supplementary earthing conductor is permitted to be made
to building steel, to a metal electrical raceway system, or to any earthed item that is
permanently and reliably connected to the electrical service equipment earthed.
Bare, covered, or insulated earthing conductors are acceptable. A covered or insulated
conductor must have a continuous outer finish that is either green, or green with one or
more yellow stripes.
A readily accessible disconnect device, that is suitably approved and rated, shall be
incorporated in the field wiring.
Maximum recommended ambient operating temperature is 50
°C.
ADTRAN does not recommend using the optional battery backup unit when the
NetVanta 6250 is being powered from a DC source.