Chapter 2. Installation and Operation
28 T3SU 300 User Manual 61202217L1-1C
Rubber feet for stand-alone use
Customer Provides
The customer provides an interface cable for each port used. Each
cable should be either HSSI, V.35, or an 8-pin modular cable,
depending on the interface type.
POWER UP
The T3SU 300 is provided with a captive eight-foot power cord,
terminated by a three-prong plug which connects to a grounded
115 VAC power receptacle.
A three-position terminal block which accommodates 12 to 26
AWG wire is located on the rear panel of the T3SU 300 DC version.
The positive (+) and negative (-) terminals connect to a -24 to
-48 VDC, 0.4A power source. Figure 2-1 on page 29 provides an
illustration of the terminal block power connector, along with
definitions for the three connector symbols.
The ADTRAN T3SU 300 MIB is available in the support section of
the ADTRAN web page at www.adtran.com.
Power to the T3SU 300 must be provided from a grounded 115
VAC, 60 Hz receptacle.
The chassis should be connected to an earth ground.