61202217L1-1C T3SU 300 User Manual 41
Figure 3-2. DS3 Network Configuration Menu
DS3 Framing
Set the framing format to match the format of the receive signal at
the network interface.
C-BIT PARITY and M13 framing formats are
supported. Select
AUTO to allow the interface to detect the framing
type automatically.
Line Length
Set the line length to reflect the physical length of the DS3 network
line. Set to
LONG if the cabling distance exceeds 225 feet; set to
SHORT if the distance is less than 225 feet.
DS3 Timing
Set the timing to LOOP if the T3SU 300 is to derive timing from the
network; set to
LOCAL if the unit is to be the master timing source
for the circuit. In most cases, the unit should be configured for
LOOP timing.