ADTRAN TSU LT User Manual Page 37

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 36
TSU LT 220V User Manual Chapter 5 Config Menu
61203060L2-1A © 2004 ADTRAN, Inc. 37
Network Timing
The network is the source of timing. The received data clocking is looped back to the network, where it is
used to determine the transmission timing. This option is also referred to as looped timed as the
transmission clock is derived from the received clock. See Figure 5-3.
Figure 5-3. Network Timed Clock Source
DTE Timing
The DTE is the source of timing. The TSU LT 220V uses the incoming DTE clock to determine the
transmission timing. This is typically used in applications such as limited distance line drivers, where it is
necessary to have the DTE as the primary clock source (see Figure 5-4).
Figure 5-4. DTE Clock Source