TSU LT 220V User Manual Chapter 7 Test Menu
61203060L2-1A © 2004 ADTRAN, Inc. 47
Test Pattern
Selects the test pattern and initiates the transmission of the pattern. There are five patterns available (see
below). End testing by selecting
NO PATTERN.
CLR Errors
CLR ERRORS has two functions. First, it clears out the 511 error total when you press ENTER. Second, it
displays a total of the 511 errors; that is, if 511 errors are being received, the display updates accordingly.
This function is useful in testing end-to-end integrity of the network. To do this, first, loop up the far end
TSU LT, and send a 511 pattern from the local TSU LT. Then, view the
CLR ERRORS screen to determine
whether the link is functioning properly by verifying that no errors are being counted.
Insert 511 Errors
When running a 511 pattern test, press the ENTER key to insert an error into the 511 pattern.
RUN SELF-TEST
Use this menu to execute an internal self-test. This is the same self-test that is automatically performed at
power-up. After displaying
INITIALIZING, the LCD shows the results (including failures) of the self-test (see
Figure 7-3).
Figure 7-3. Self Test Results Screen
1:8 ALL DS0s
Generates a 1 in 8 pattern in all DS0s.
QRSS Active
DS0s
Generates a 4 QRSS test pattern and inserts the pattern into currently active
channels.
511 Active DS0s
Generates a 511 test pattern and inserts the pattern into currently active channels.
All Zeros
Generates an all zero's pattern in every channel.
All Ones
Generates an all one’s pattern in every channel.