TSU LT 220V User Manual Chapter 5 Config Menu
61203060L2-1A © 2004 ADTRAN, Inc. 39
Cntrl Port Submenu
Use to set up the unit as the master or slave on a chain of units, and to initialize a modem and the control
port data rate.
Alarms Submenu
Use these submenus to initialize the method by which the control port handles alarm conditions.
POSITION
[of TSU LT 220V]
This option determines whether the TSU LT 220V is at the head of a chain of units
(directly connected to the modem or PC). The head of the chain is referred to as
the master unit. Units down the chain are referred to as slaves or a slave unit.
Setting the position is only necessary when you are using a modem, in which case
the head unit should be
MASTER. For all other cases, select SLAVE. (The master is
in charge of control of the modem.)
Choices: MASTER, SLAVE
MODEM INIT
Use this option to initialize a modem, but only when the TSU LT 220V is serving
as the
MASTER unit. The modem should be physically connected to the TSU LT
220V with the power turned on prior to initialization. At this point, an
industry-standard AT command string is used to initialize the modem. The string
is also used following future power-up sequences.
Choices: ENA (enable), DISA (disable)
DATA RATE
Selects the data rate for the control port. The data rate should be consistent with all
units on a chain and with the modem and/or PC/Proxy Agent serial port.
Choices: 1200, 2400, 9600
TRAPS
Determines whether alarm conditions should automatically trigger an alarm message
(trap) to the controlling PC/Proxy Agent. The setting is for this unit, or for slaves if
this unit is a master. For applications where the
AUTO INBAND selection is not
acceptable,
TRAPS should only be enabled with the Inband selection set to ON or OFF.
Choices: ENA (enable), DISA (disable)
OUTPUT
Selects whether the alarm traps (if enabled) are sent directly, or whether the telephone
number stored in the TSU LT 220V should be dialed first (industry-standard AT dial
command sent to modem).
Choices: DIRECT, DIAL
Page view 38