ADTRAN Vanta 1335 Installation Guide Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
NetVanta 1335 Series Hardware Installation Guide Option Modules
61700515E2-34D Copyright © 2012 ADTRAN, Inc. 23
NetVanta T1/FT1 NIM (P/N 1202862L1)
The NetVanta T1/FT1 NIM (see Figure 5) provides a T1 WAN interface for the NetVanta. This module provides
a full T1 or fractional T1 network interface. Refer to Appendix A on page 43 for WAN-T1 and DBU connector
pinouts. An optional DIM is required for dial backup applications.
Figure 5. NetVanta T1/FT1 NIM
WAN-T1 DBU
Features and Specifications
Operating Modes
Frame Relay, Multilink Frame Relay
PPP, Multilink PPP
HDLC
T1/FT1 Interface
Supported Standards: AT&T TR 62411,
AT&T TR 65016, ANSI T1.403,
Bellcore TR 194
Line Rate: 1.544 Mbps +
75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples
of 64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build-Out: 0, -7.5, -15, -22.5 dB
(long), 0 to 655 ft (short)
DS0 Assignment: Programmable
Connector: RJ-48C
Clock Source
•Network
•Internal
Diagnostics
Test Pattern Generation and Detection:
511, QRSS, all ones, all zeros
Network loopbacks (local and remote);
responds to both inband and FDL loop
codes
Alarm generation and detection
Network and user sets of performance data
(15 minutes and 24 hours)
Compliance
EMC - see Electromagnetic Compatibility
(EMC) Table on page 6.
ACTA/FCC Part 68
IC CS-03
UL/CUL 60950
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent,
noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D
Page view 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 47 48