Page view 9
Total Access 3000/3010 T1-OR/NIU Installation and Maintenance Practice
2 61181310L2-5D
Description
The T1-OR/NIU enhances existing T1 repeater spans. The T1-OR/NIU provides trouble-
shooting capabilities through either locally or remotely-programmed options and loopbacks.
The T1-OR/NIU receive-transmission-path provides a long-haul regenerator, followed by a
provisionable DSX pre-equalizer, and its transmit path provides a short-haul regenerator
followed by a provisionable transmit line build-out. The T1-OR/NIU is equipped with a DSX-
level interface to the equipment side and provides independent monitoring jacks at DSX and
T1 sides. In addition, the T1-OR/NIU provides both DSX and multiplexer (MUX) position
connections with appropriate switching logic.
Features
The basic features of the Total Access 3000/3010 T1-OR/NIU include the following:
Screen provisioning and troubleshooting via menus through the System Controller Unit (SCU)
ESF and SF compatibility
Provisionable DS1 Line Build Out (0 to –22.5 dB)
Provisionable DSX–1 Line Build Out (0 to 655 feet in 133 foot increments)
AMI and B8ZS compatible
Provisionable span power
Addressable loopbacks
DSX monitor jacks
Front panel Bantam jacks and span power test points
Seven day storage and real-time performance monitoring information
Compliance
Table 1 shows the compliance codes for the T1-OR/NIU. The T1-OR/NIU is NRTL listed to the
applicable UL standards. Install the T1-OR/NIU in a restricted access location and in a type
“B” or “E” enclosure only.
Table 1. Compliance Codes
Configuration Code Input Output
Power Code (PC) F X
Telecommunication Code (TC) X
Installation Code (IC) A