ADTRAN Total Access 3000 Specifications Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
Total Access 3000/3010 T1-OR/NIU Installation and Maintenance Practice
10 61181310L2-5D
Total Access 3000 Chassis Amphenol Connectors
The Total Access 3000 shelf delivers DSX-1 from the network to the T1-OR/NIU through
connectors on the backplane labeled
Pair 7 and Pair 8. The DS1 signal is provided through the
backplane connectors labeled
Pair 1 and Pair 2.
Pins 1 and 33 of the connectors Pair 7 and Pair 8 are the DSX connections for the T1-OR/NIU
in slot 1. Pins 2 and 34 of these connectors are associated with slot 2. Pins 3 and 35 are
associated with slot 3, and so forth, up to pins 28 and 60 for slot 28. Table 5 provides the pin
numbers of the Total Access 3000 backplane Amphenol connectors.
Table 5. Total Access 3000/3010 Backplane Connector Pinout
Slot
Total Access 3000/3010
Loop Pair 1 and Pair 2 (DS1 Side)
DSX-1 Pair 7 and Pair 8 (DSX-1 Side)
1 1/33 1/33
2 2/34 2/34
3 3/35 3/35
4 4/36 4/36
5 5/37 5/37
6 6/38 6/38
7 7/39 7/39
8 8/40 8/40
9 9/41 9/41
10 10/42 10/42
11 11/43 11/43
12 12/44 12/44
13 13/45 13/45
14 14/46 14/46
15 15/47 15/47
16 16/48 16/48
17 17/49 17/49
18 18/50 18/50
19 19/51 19/51
20 20/52 20/52
21 21/53 21/53
22 22/54 22/54
23 23/55 23/55
Page view 17