SCU Control Port Operation
61181310L2-5D 17
Provisioning
Provisioning the module provides setup and configuration information that allows the module
to conform to local network standards of operation, including framing format, transmit level
line coding and network source. Network Administration maintains this information on each
circuit.
Office Repeater Mode
The Provisioning menu (Figure 12) for each mode lists option categories and the current
option selection for each. Enter the number for a category to advance the screen display to a
new screen providing the options for that category. Enter
D to restore the factory default
options for the entire list.
On this menu, the Card Configuration option selects the appropriate mode for the intended
application (T1-OR or NIU).
Figure 12. Provisioning Menu-OR Mode
Table 6 provides descriptions and defaults for the Provisioning menu options.
CAUTION
Do not make provisioning option changes when the Service State is
set to In Service. Make option changes in an Out-of-Service state
only.
Shelf: 1 Slot: 12 Total Access System 12/29/05 09:29
Unacknowledged Alarms: None
CIRCUIT ID:
Provisioning
1. DSX-1 Line Buildout = 0-133 Feet
2. DSX-1/DS1 Line Code = B8ZS
3. DSX-1/DS1 Framing = ESF
4. Loopback Timeout = 120 Min
5. DS1 TX Level = 0 dB
6. Network Source = DSX/DS1
7. Service State = OOS Unassigned
8. Span Power = Disabled
9. External Alarms = Disabled
10. Card Configuration = T1-OR
11. AIS = Disabled
D. Restore Factory Defaults
‘?’ - System Help Screen
Selection: